Outdoor Lighting | Catalog Downlight | Catalog - Formerly Infinity Fluorescent Lighting | Catalog

H. E. Williams, Inc.

Warranty, Terms & Conditions
Payment terms, freight allowances, drop shipments, pricing policy, delivery dates, hold orders, order changes/cancellations, claims, returns, fixture warranty, ballast guarantee, exclusions, liabilities, indemnity, risk, merger, assignment, governing law.
Ballast Disconnect CEC compliance statement
Ballast Disconnect NEC compliance statement
Drywall Flange Kit (-DFK)
Allows use of any Williams grid troffer in ceilings that require a flange product
Earthquake Clips (-EQCLIPS)
Combination earthquake clip and NEC T-bar secures luminary to T-bar and prevents T-system separation.
Electrical Accessories
6' Cord/Plug 120V(-6CPI/5-15P), 277V(-6CPI/7-15P), Fast(-GLR) & Slow(-GMF) Fuse, Ballast Suppressor(-RIF), Ballast Mount(-4BM)
Feeder/Joiner/Canopies
Suspended Architectural light fixture mounting hardware & canopies
Gaskets
Double Gasket(-DG) & Triple Gasket(-TG) aluminum door frames
Ballast Logic
Unless otherwise specified, Williams fixtures are provided with generic ballasts. All ballasts are by high quality, industry recognized manufacturers. The term generic only means factory choice of ballast manufacturer utilized.
Grid Riser Spec Sheet
Elevated troffer provides skylight effect which increases the architectural appearance of any space. Compatible with all Williams recessed troffer's and many competitor products
Lamp & Ballast Warranty Contact Information
Lamps and ballasts are warranted by their respective manufacturers, not H.E. Williams, Inc. To replace defective lamps and ballasts, please contact the lamp or ballast manufacturer.
Lamp Types/Ordering
A wide variety of Williams recessed troffers and certain suspended architectural fixtures are available with lamps furnished and installed in the fixture.
Master-Satellite Systems
Master units (-M9A, -M9B, -M9C, -M9D, -M9E, or -M9F) have 9' flexible wiring cable. Satellite units are designated as 2x3-lamp(-SA or -SD), 2x4-lamp(-SB), 2x2-lamp(-SC or -SF), 2x1-lamp(-SE), and Master-Satellite light fixture systems.
Mounting Systems
Sway adapters, single/double stem/swivel canopies, hangers, spacers, GAT fasteners, louvers, strip wire-guards
Occupancy Sensors
Occupancy sensors have long been used as a tool to help manage lighting-related energy costs. While maximized lights-off time cuts electrical use, there is considerable evidence that shorter switching cycles reduce fluorescent lamp life.
Quick-Connect Wiring and Components
Designed specifically to save labor installation costs, the QC option utilizes a molded nylon self-locking polarized connector with factory installed branch circuit wiring. Fixtures simply plug together, and the possibility of cross wiring is eliminated. All H.E. Williams recessed troffers are available with a flexible metallic wiring harness, factory attached and hard wired to the luminary.
Color-match with RAL® Colors
Since 1927, RAL® has created a uniform language when it comes to color. They have standardized, numbered and named the abundance of colors. These standards are easily understandable and applicable worldwide.
Shielding/Louvers
#12, #15, #19, dished white acrylic shielding, 1/2" and 1-1/2" deep white, gold, or silver plastic parabolic louvers, and 3/4" 1-1/4", and 1-1/2" aluminum parabolic louvers for the 50 and EP series troffers.
Tandem In-Line Wiring
Fixtures are installed end-to-end in pairs. Secondary wiring is completed by linking polarized cap and plug connector from each section. 2x1-lamp(-TW1), 2x2-lamp(-TW2), 1x4-lamp(-TW3), 2x3-lamp(-TW5 or -TW6)
Williams IES Files
Download and run this self-extracting file and it will create a folder called c:\IES_files\Williams\ and place all available IES photometric files on your computer.
REVIT Files (for BIM software applications)
All Williams Fluorescent and Downlighting REVIT files in one Zip file.
Cylinder Features/Options
Cylinder Mounting Options
Williams Downlighting Universal Mounting System allows the same style cylinder to be mounted several different ways to fit your specific application. This is a great benefit when coordinating fixtures throughout a building or campus. Custom colors help create unique architectural accents.
DRM (Dark Room Light) Filter Options
Photo material compatibility chart, descriptions, & Kodak suffix's.
Induction Mounting Options
Lamp & Ballast Warranty Contact Information
Lamps and ballasts are warranted by their respective manufacturers, not H.E. Williams, Inc. To replace defective lamps and ballasts, please contact the lamp or ballast manufacturer.
Lamp Comparison
Quick guide to lamp performance and specifics. Consult lamp manufacture for detailed information.
Luminous Glass
Decorative clear and colored disks, rings, & shields.
LV45 Trim Options
Occupancy Sensors
Occupancy sensors have long been used as a tool to help manage lighting-related energy costs. While maximized lights-off time cuts electrical use, there is considerable evidence that shorter switching cycles reduce fluorescent lamp life.
Color-match with RAL® Colors
Since 1927, RAL® has created a uniform language when it comes to color. They have standardized, numbered and named the abundance of colors. These standards are easily understandable and applicable worldwide.
Recessed Lighting Product Features
Reflector Colors
For an added touch of distinction you may choose a reflector color that will coordinate with the colors of your building's interior and enhance the color characteristics of the lamp source.
Retrofit Mounting Pan
Use the retrofit mounting pan when remodeling or replacing fixtures where there is a finished ceiling with fixed apertures. The retrofit mounting pan is cut out on one side to “hook” the assembly through an existing hole. Two available pans accommodate round reflector sizes 6", 7½", 8½", 10", & 12".
Sloped Ceiling Adapter with Pan Assembly
Spun aluminum sloped ceiling adaptors are available in increments of 5 degrees from 10°—30°. Sloped ceiling adapters are available for Downlighting recessed light fixtures with “SCA” option. Consult factory for height.
Options & Accessory Designations
This .pdf document explains what all of the Downlighting line number designations, such as BH, POLY, QRS, and etc. mean.
Square Trims
Drop Opal, Drop Acrylic, C73 & Fresnel Lenses & splays.
Downlighting IES Files
Download and run this self-extracting file and it will create a folder called c:\IES_files\Infinity\ and place all available IES photometric files on your computer.
REVIT Files (for BIM software applications)
All Williams Fluorescent and Downlighting REVIT files in one Zip file.
Anchor Bolt Templates—Bollards
Mounting Template for 6" and 8" Aluminum Bollards
Mounting Template for 8", 10" and 12" Concrete Bollards
Anchor Bolt Templates—Decorative Poles
AV10 & AV30—Aluminum Poles
AV20, AV50 & AV60—Aluminum Poles
AV40—Aluminum Pole
AV40—Steel Pole
Anchor Bolt Templates—Historic Poles
HHNF & HHNR
HSCF & HSCR
HWLF & HWLR
HWNF & HWNR
Anchor Bolt Templates—Standard Poles
RSA & RTA—Round Straight/Tapered Aluminum Poles
SSA—Square Straight Aluminum Poles
RSS—Round Straight Steel Pole
RTS—Round Tapered Steel Pole
SSS—Square Straight Steel Pole
STS—Square Tapered Steel Pole
Color-match with RAL® Colors
Since 1927, RAL® has created a uniform language when it comes to color. They have standardized, numbered and named the abundance of colors. These standards are easily understandable and applicable worldwide.
Lamp & Ballast Warranty Contact Information
Lamps and ballasts are warranted by their respective manufacturers, not H.E. Williams, Inc. To replace defective lamps and ballasts, please contact the lamp or ballast manufacturer.
Williams Outdoor Lighting Lamp Specification Information
How to specify Pulse Start Metal Halide (PSM) and High Pressure Sodium (HPS) lamps with Williams Outdoor lighting.
Standard Pole Information
TNRA—Round Aluminum Pole Top Tenon Mount
TNRSRound Steel Pole Top Tenon Mount
TNSASquare Aluminum Pole Top Tenon Mount
TNSSSquare Steel Pole Top Tenon Mount
Wind Map
North American wind velocity map for outdoor light pole design.